Tel:021-37012001
Fax:021-37012002
Email:shcxslae@126.com
Address:No. 328 Hengyong Road, Jiading District, Shanghai
OVERVIEW:
Matel tube flowmeter based on the float principle are versatile and can be used for conductive and non-conducting liquids and gases. The sturdy all-metal design ensures high resistance to pressure, temperature and media and stands up to extreme application and environmental conditions. The position of the float is magnetically transmitted to an analog indicator to display the measurement without auxiliary power.After the angle sensor and subsequent circuit amplification, the standard industrial signal output and liquid crystal display are formed.
OPERATING PRINCPLE:
The flow measurement is accomplished by the transmitter in the indicator through coupling the magnetic steel to sense the change of the float position. When the measured medium flows through the measuring tube from bottom to top, and the float is balanced by gravity, buoyancy and fluid velocity, the float is relatively stationary at a certain position, which changes with the annular gap area between the float and the cone tube and the fluid velocity, and the position of the float corresponds to the flow rate of the measured medium.
MEDIUM:
liquid ,gas,steam
Product Parameters
measuring range | Water (20ºC) 16~150000 l/h. Air(0.1013MPa 20ºC) 0.5~4000 m3/h. |
Range ratio | 10:1 |
Accuracy class | 2.5(Special type 1.5% or 1.0%). |
Working pressure | PN16,PN25,PN40 |
Medium temperature | Normalized type -20ºC~+80ºC.
|
Ambient temperature | -10ºC~+60ºC |
Output | Standard signal: two-wire system 4 ~ 20mA (with HART communication). Standard signal: three-wire system 0 ~ 10mA. Alarm signal:1.Two-way relay output. 2.One-way or two-approach switches . Pulse signal output: 0-1KHz isolated output. |
Power Supply | 24VDC or 3.6V Battery
|
Process Connection | Flange Thread Tri-clamp |
Levels of protection | IP65/IP67. |
Ex-mark | Intrinsically safe:ExiaIICT3~6. Exd type:ExdIICT4~6. |
百度统计