      VF  type  vortex flow meter is widely used in the measurement and control of superheated steam, saturated steam, compressed air and general gas (oxygen, nitrogen, hydrogen, natural gas, gas, etc.), water and liquid (such as water, gasoline, alcohol, benzene, etc.) in petroleum, chemical, metallurgical, thermal, textile, paper and other industries.   


Operating Principle:
      
In a fluid set bluff vortex generating body ( blocking fluid ), from both sides of the vortex generating body producing alternately two regular vortex, the vortex called Kaman vortex.                           
        Vortex is arranged below the vortex generator non symmetrically.f:the vortex frequency,V: The average flow rate of the liquid,d: the width of the vortex generating body, D:the pipe diameter,Formula as below:
         f=StV/d 
           formula parameter:
               f-carmen vortex frequency                                
               St-strouhal number
               V-The average flow rate of the liquid
               d-the width of the vortex generating body
        Thus we could calculate the flowmeter according to the vortex frequcency.
         In the curve St = 0.17 straight section, whirlpool release frequency and velocity proportional to, namely the vortex flow sensor measurement range. As long as the detected frequency f can be obtained within the tube by the flow rate of the fluid, flow velocity and volume flow rate V. The measured pulse number and volume ratio is called the instrument constant ( K ),see formula two
                       K=N/Q(1/m³)           
                  definition:
                       K=constant(1/m³).
                       N=pulse count
                       Q=volume flowmeter(m³)
Medium:
      
Normal TEMP.:GAS,LIQUID(<100ºC)
        MID      TEMP.:GAS ,LIQUID, STEAM(100-250ºC)
        Hight    TEMP: GAS,LIQUID,STEAM(150-350ºC)


Product Parameters

diameter(mm)15,25,32,40,50,65,80,100,125,150,200,250,300,(300~1000 insert type)
pressure(MPa)DN15-DN200 4.0(>4.0 customized),DN250-DN300 1.6(>1.6 customized)
temperature(ºC)Piezoelectric type:-40~260,-40~320;capacitance type: -40~300, -40~400,-40~450(customized)
Body material1Cr18Ni9Ti,(customized if else material)
accelerationPiezoelectric type:0.2g      capacitance type:1.0~2.0g
accuracy±1%R,±1.5%R,±1FS;insert type:±2.5%R,±2.5%FS
span1:6~1:30
Power supplysensor:+12V DC,+24V DC;converter:+12V DC ,+24V DC;battery:3.6V
Output signalSquare pulse(not included battery):high level≥5V,low level≤1V;current:4~20mA;HART,RS485
Pressure loss coefficientComform to the standard JB/T9249 Cd≤2.4
Explosion gradeex:ExdIIa CT2-T5   flameproof type:ExdIICT2-T5     
Protection gradeNormal IP65     scuba diving IP68
environmentationTemperature:-20ºC~55ºC,humidity:5%~90%,gas pressure:86~106kPa
mediumgas,liquid,steam
Trans distancePulse type:≤300m,current type: (4~20mA):load resistance:≤750Ω


Reference conditions of vortex flow sensors flow rate range table

c60d2f9d8c61ed24afb78db0fb9b90b.png

END

Tags

Recently Viewed:

  • menu
record number:沪ICP备19033489号

百度统计

Contact
  • 1
    总机:(+86)021-37017603
    销售直线:(+86)021-37012001
  • 2
    邮箱: shcxsale@126.com
    shcxsales@126.com
  • 3
    地址: 上海市嘉定区恒永路328号
底部二维码
© Copyright 2024. All Rights Reserved- Shanghai Gexin Automation Instrument Co., Ltd Technical Support: 华企博网
#
在线客服

x